Application:
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.
Property:
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.
Specification:
Standard:
IEC60502,designing and manufacturing special power cable according to the other standards required by the customers.
1) 3.6/6(7.2)kV,3.6/6.6(7.2)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath |
Approx. Overall Dia. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
25 |
6.0 |
2.5 |
0.12 |
1.5 |
17.6 |
0.34 |
0.49 |
1.2000 |
0.7270 |
35 |
7.0 |
2.5 |
0.12 |
1.5 |
18.5 |
0.39 |
0.60 |
0.8680 |
0.5240 |
50 |
8.3 |
2.5 |
0.12 |
1.6 |
20.0 |
0.46 |
0.74 |
0.6410 |
0.3870 |
70 |
9.7 |
2.5 |
0.12 |
1.6 |
21.5 |
0.55 |
0.96 |
0.4430 |
0.2680 |
95 |
11.3 |
2.5 |
0.12 |
1.7 |
23.3 |
0.66 |
1.23 |
0.3200 |
0.1930 |
120 |
13 |
2.5 |
0.12 |
1.7 |
24.8 |
0.77 |
1.48 |
0.2530 |
0.1530 |
150 |
14.6 |
2.5 |
0.12 |
1.8 |
26.4 |
0.87 |
1.77 |
0.2060 |
0.1240 |
185 |
15.9 |
2.5 |
0.12 |
1.8 |
28.1 |
1.01 |
2.13 |
0.1640 |
0.0991 |
240 |
18.3 |
2.6 |
0.12 |
1.9 |
30.9 |
1.23 |
2.71 |
0.1250 |
0.0754 |
300 |
20.4 |
2.8 |
0.12 |
2.0 |
33.6 |
1.48 |
3.32 |
0.1000 |
0.0601 |
400 |
23.2 |
3.0 |
0.12 |
2.1 |
37.0 |
1.81 |
4.16 |
0.0778 |
0.0470 |
500 |
26.4 |
3.2 |
0.12 |
2.2 |
41.1 |
2.24 |
5.27 |
0.0605 |
0.0366 |
630 |
30.1 |
3.2 |
0.12 |
2.3 |
45.0 |
2.73 |
6.62 |
0.0469 |
0.0283 |
2) 6/10(12)kV,6.35/11(12)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath |
Approx. Overall Dia. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
|||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
|||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
|
25 |
6.0 |
3.4 |
0.12 |
1.5 |
19.4 |
0.40 |
0.55 |
1.2000 |
0.7270 |
|
35 |
6.9 |
3.4 |
0.12 |
1.6 |
20.5 |
0.45 |
0.66 |
0.8680 |
0.5240 |
|
50 |
8.2 |
3.4 |
0.12 |
1.6 |
21.8 |
0.52 |
0.80 |
0.6410 |
0.3870 |
|
70 |
9.7 |
3.4 |
0.12 |
1.7 |
23.5 |
0.62 |
1.03 |
0.4430 |
0.2680 |
|
95 |
11.3 |
3.4 |
0.12 |
1.7 |
25.1 |
0.73 |
1.30 |
0.3200 |
0.1930 |
|
120 |
12.8 |
3.4 |
0.12 |
1.8 |
26.8 |
0.85 |
1.56 |
0.2530 |
0.1530 |
|
150 |
14.2 |
3.4 |
0.12 |
1.8 |
28.2 |
0.95 |
1.85 |
0.2060 |
0.1240 |
|
185 |
15.9 |
3.4 |
0.12 |
1.9 |
30.1 |
1.10 |
2.22 |
0.1640 |
0.0991 |
|
240 |
18.3 |
3.4 |
0.12 |
2.0 |
32.7 |
1.33 |
2.80 |
0.1250 |
0.0754 |
|
300 |
20.4 |
3.4 |
0.12 |
2.0 |
34.8 |
1.54 |
3.39 |
0.1000 |
0.0601 |
|
400 |
23.2 |
3.4 |
0.12 |
2.2 |
38.0 |
1.87 |
4.22 |
0.0778 |
0.0470 |
|
500 |
26.4 |
3.4 |
0.12 |
2.2 |
41.5 |
2.26 |
5.29 |
0.0605 |
0.0366 |
|
630 |
30.1 |
3.4 |
0.12 |
2.4 |
45.6 |
2.78 |
6.67 |
0.0469 |
0.0283 |
3) 8.7/10(15)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath |
Approx. Overall Dia. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
|||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
|||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
|
25 |
6.0 |
4.5 |
0.12 |
1.6 |
21.8 |
0.48 |
0.63 |
1.2000 |
0.7270 |
|
35 |
6.9 |
4.5 |
0.12 |
1.7 |
22.9 |
0.54 |
0.75 |
0.8680 |
0.5240 |
|
50 |
8.2 |
4.5 |
0.12 |
1.7 |
24.2 |
0.61 |
0.89 |
0.6410 |
0.3870 |
|
70 |
9.7 |
4.5 |
0.12 |
1.8 |
25.9 |
0.72 |
1.13 |
0.4430 |
0.2680 |
|
95 |
11.3 |
4.5 |
0.12 |
1.8 |
27.5 |
0.84 |
1.40 |
0.3200 |
0.1930 |
|
120 |
12.8 |
4.5 |
0.12 |
1.9 |
29.2 |
0.96 |
1.67 |
0.2530 |
0.1530 |
|
150 |
14.2 |
4.5 |
0.12 |
1.9 |
30.6 |
1.06 |
1.96 |
0.2060 |
0.1240 |
|
185 |
15.9 |
4.5 |
0.12 |
2.0 |
32.5 |
1.22 |
2.34 |
0.1640 |
0.0991 |
|
240 |
18.3 |
4.5 |
0.12 |
2.1 |
35.1 |
1.46 |
2.93 |
0.1250 |
0.0754 |
|
300 |
20.4 |
4.5 |
0.12 |
2.1 |
37.2 |
1.68 |
3.52 |
0.1000 |
0.0601 |
|
400 |
23.2 |
4.5 |
0.12 |
2.2 |
40.2 |
2.00 |
4.35 |
0.0778 |
0.0470 |
|
500 |
26.4 |
4.5 |
0.12 |
2.3 |
43.9 |
2.43 |
5.45 |
0.0605 |
0.0366 |
|
630 |
30.1 |
4.5 |
0.12 |
2.4 |
47.8 |
2.93 |
6.83 |
0.0469 |
0.0283 |
4) 12/20(24)kV, 12.7/22(24)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath |
Approx. Overall Dia. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
25 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
35 |
6.9 |
5.5 |
0.12 |
1.7 |
24.9 |
0.62 |
0.83 |
0.8680 |
0.5240 |
50 |
8.2 |
5.5 |
0.12 |
1.8 |
26.4 |
0.70 |
0.98 |
0.6410 |
0.3870 |
70 |
9.7 |
5.5 |
0.12 |
1.8 |
27.9 |
0.80 |
1.21 |
0.4430 |
0.2680 |
95 |
11.3 |
5.5 |
0.12 |
1.9 |
29.7 |
0.94 |
1.50 |
0.3200 |
0.1930 |
120 |
12.8 |
5.5 |
0.12 |
1.9 |
31.2 |
1.05 |
1.77 |
0.2530 |
0.1530 |
150 |
14.2 |
5.5 |
0.12 |
2.0 |
32.8 |
1.17 |
2.07 |
0.2060 |
0.1240 |
185 |
15.9 |
5.5 |
0.12 |
2.0 |
34.5 |
1.33 |
2.45 |
0.1640 |
0.0991 |
240 |
18.3 |
5.5 |
0.12 |
2.1 |
37.1 |
1.57 |
3.04 |
0.1250 |
0.0754 |
300 |
20.4 |
5.5 |
0.12 |
2.2 |
39.4 |
1.81 |
3.66 |
0.1000 |
0.0601 |
400 |
23.2 |
5.5 |
0.12 |
2.3 |
42.4 |
2.14 |
4.49 |
0.0778 |
0.0470 |
500 |
26.4 |
5.5 |
0.12 |
2.4 |
46.1 |
2.58 |
5.61 |
0.0605 |
0.0366 |
630 |
30.1 |
5.5 |
0.12 |
2.4 |
49.8 |
3.10 |
6.99 |
0.0469 |
0.0283 |
5) 18/30(36)kV,19/33(36)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath |
Approx. Overall Dia. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
|||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
|||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
|
25 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
|
35 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
|
50 |
8.2 |
8.0 |
0.12 |
2.0 |
31.8 |
0.95 |
1.23 |
0.6410 |
0.3870 |
|
70 |
9.7 |
8.0 |
0.12 |
2.0 |
33.3 |
1.07 |
1.47 |
0.4430 |
0.2680 |
|
95 |
11.3 |
8.0 |
0.12 |
2.1 |
35.1 |
1.21 |
1.78 |
0.3200 |
0.1930 |
|
120 |
12.8 |
8.0 |
0.12 |
2.1 |
36.6 |
1.34 |
2.05 |
0.2530 |
0.1530 |
|
150 |
14.2 |
8.0 |
0.12 |
2.2 |
38.2 |
1.47 |
2.37 |
0.2060 |
0.1240 |
|
185 |
15.9 |
8.0 |
0.12 |
2.2 |
39.9 |
1.64 |
2.76 |
0.1640 |
0.0991 |
|
240 |
18.3 |
8.0 |
0.12 |
2.3 |
42.5 |
1.90 |
3.37 |
0.1250 |
0.0754 |
|
300 |
20.4 |
8.0 |
0.12 |
2.4 |
44.8 |
2.16 |
4.01 |
0.1000 |
0.0601 |
|
400 |
23.2 |
8.0 |
0.12 |
2.4 |
47.6 |
2.52 |
4.87 |
0.0778 |
0.0470 |
|
500 |
26.4 |
8.0 |
0.12 |
2.5 |
51.3 |
2.98 |
6.01 |
0.0605 |
0.0366 |
|
630 |
30.1 |
8.0 |
0.12 |
2.6 |
55.2 |
3.54 |
7.43 |
0.0469 |
0.0283 |
6) 3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath |
Approx. Overall Dia. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
||||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
||||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
||
25 |
6.0 |
2.5 |
0.1 |
2.0 |
34.6 |
1.13 |
1.58 |
1.2000 |
0.7270 |
||
35 |
6.9 |
2.5 |
0.1 |
2.1 |
36.8 |
1.29 |
1.92 |
0.8680 |
0.5240 |
||
50 |
8.2 |
2.5 |
0.1 |
2.2 |
39.8 |
1.51 |
2.36 |
0.6410 |
0.3870 |
||
70 |
9.7 |
2.5 |
0.1 |
2.3 |
43.2 |
1.81 |
3.04 |
0.4430 |
0.2680 |
||
95 |
11.3 |
2.5 |
0.1 |
2.4 |
46.9 |
2.17 |
3.87 |
0.3200 |
0.1930 |
||
120 |
12.8 |
2.5 |
0.1 |
2.4 |
50.1 |
2.53 |
4.69 |
0.2530 |
0.1530 |
||
150 |
14.2 |
2.5 |
0.1 |
2.5 |
53.3 |
2.90 |
5.60 |
0.2060 |
0.1240 |
||
185 |
15.9 |
2.5 |
0.1 |
2.6 |
57.2 |
3.40 |
6.77 |
0.1640 |
0.0991 |
||
240 |
18.3 |
2.6 |
0.1 |
2.8 |
63.2 |
4.12 |
8.55 |
0.1250 |
0.0754 |
||
300 |
20.4 |
2.8 |
0.1 |
3.0 |
69.0 |
4.89 |
10.46 |
0.1000 |
0.0601 |
||
400 |
23.2 |
3.0 |
0.1 |
3.4 |
76.7 |
6.10 |
13.18 |
0.0778 |
0.0470 |
||
500 |
26.4 |
3.2 |
0.1 |
3.6 |
85.7 |
8.10 |
16.55 |
0.0605 |
0.0366 |
7) 6/10(12)kV,6.35/11(12)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath |
Approx. Overall Dia. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
|||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
|||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
|
25 |
6.0 |
3.4 |
0.1 |
2.1 |
38.7 |
1.30 |
1.75 |
1.2000 |
0.7270 |
|
35 |
6.9 |
3.4 |
0.1 |
2.2 |
40.9 |
1.47 |
2.22 |
0.8680 |
0.5240 |
|
50 |
8.2 |
3.4 |
0.1 |
2.3 |
43.9 |
1.70 |
2.50 |
0.6410 |
0.3870 |
|
70 |
9.7 |
3.4 |
0.1 |
2.4 |
47.3 |
2.02 |
3.25 |
0.4430 |
0.2680 |
|
95 |
11.3 |
3.4 |
0.1 |
2.5 |
51.0 |
2.42 |
4.12 |
0.3200 |
0.1930 |
|
120 |
12.8 |
3.4 |
0.1 |
2.6 |
54.4 |
2.79 |
4.95 |
0.2530 |
0.1530 |
|
150 |
14.2 |
3.4 |
0.1 |
2.7 |
57.6 |
3.17 |
5.87 |
0.2060 |
0.1240 |
|
185 |
15.9 |
3.4 |
0.1 |
2.8 |
61.5 |
3.69 |
7.06 |
0.1640 |
0.0991 |
|
240 |
18.3 |
3.4 |
0.1 |
2.9 |
66.9 |
4.38 |
8.82 |
0.1250 |
0.0754 |
|
300 |
20.4 |
3.4 |
0.1 |
3.1 |
71.8 |
5.11 |
10.68 |
0.1000 |
0.0601 |
|
400 |
23.2 |
3.4 |
0.1 |
3.3 |
78.3 |
6.24 |
13.32 |
0.0778 |
0.0470 |
|
500 |
26.4 |
3.4 |
0.1 |
3.5 |
86.4 |
7.63 |
16.50 |
0.0605 |
0.0366 |
8) 8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath |
Approx. Overall Dia. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
||||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
||||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
||
25 |
6.0 |
4.5 |
0.1 |
2.3 |
43.9 |
1.57 |
2.02 |
0.9270 |
0.7270 |
||
35 |
6.9 |
4.5 |
0.1 |
2.4 |
46.0 |
1.75 |
2.38 |
0.6680 |
0.5240 |
||
50 |
8.2 |
4.5 |
0.1 |
2.4 |
48.8 |
2.00 |
2.85 |
0.4936 |
0.3870 |
||
70 |
9.7 |
4.5 |
0.1 |
2.5 |
52.3 |
2.34 |
3.57 |
0.3420 |
0.2680 |
||
95 |
11.3 |
4.5 |
0.1 |
2.6 |
55.9 |
2.75 |
4.45 |
0.2464 |
0.1930 |
||
120 |
12.8 |
4.5 |
0.1 |
2.7 |
59.4 |
3.16 |
5.32 |
0.1955 |
0.1530 |
||
150 |
14.2 |
4.5 |
0.1 |
2.8 |
62.6 |
3.57 |
6.27 |
0.1587 |
0.1240 |
||
185 |
15.9 |
4.5 |
0.1 |
2.9 |
66.4 |
4.07 |
7.45 |
0.1271 |
0.0991 |
||
240 |
18.3 |
4.5 |
0.1 |
3.1 |
72.0 |
4.82 |
9.25 |
0.0976 |
0.0754 |
||
300 |
20.4 |
4.5 |
0.1 |
3.3 |
77.0 |
5.71 |
11.28 |
0.0778 |
0.0601 |
||
400 |
23.2 |
4.5 |
0.1 |
3.4 |
83.2 |
6.78 |
13.86 |
0.0615 |
0.0470 |
||
500 |
26.4 |
4.5 |
0.1 |
3.5 |
91.1 |
8.20 |
17.32 |
0.0487 |
0.0366 |
9) 12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath |
Approx. Overall Dia. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
||||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
||||||||
mm2 |
mm |
mm |
mm2 |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
||
25 |
- |
 |
 |
 |
 |
 |
 |
 |
 |
||
35 |
6.9 |
5.5 |
0.1 |
2.4 |
50.3 |
2.00 |
2.63 |
0.8680 |
0.6680 |
||
50 |
8.2 |
5.5 |
0.1 |
2.5 |
53.3 |
2.26 |
3.11 |
0.6410 |
0.4936 |
||
70 |
9.7 |
5.5 |
0.1 |
2.6 |
56.8 |
2.62 |
3.85 |
0.4430 |
0.3420 |
||
95 |
11.3 |
5.5 |
0.1 |
2.8 |
60.6 |
3.07 |
4.77 |
0.3200 |
0.2464 |
||
120 |
12.8 |
5.5 |
0.1 |
2.9 |
64.1 |
3.49 |
5.65 |
0.2530 |
0.1955 |
||
150 |
14.2 |
5.5 |
0.1 |
3.0 |
67.3 |
3.91 |
6.61 |
0.2060 |
0.1587 |
||
185 |
15.9 |
5.5 |
0.1 |
3.1 |
71.2 |
4.44 |
7.81 |
0.1640 |
0.1271 |
||
240 |
18.3 |
5.5 |
0.1 |
3.3 |
76.8 |
5.21 |
9.64 |
0.1250 |
0.0976 |
||
300 |
20.4 |
5.5 |
0.1 |
3.3 |
81.3 |
6.10 |
11.66 |
0.1000 |
0.0778 |
||
400 |
23.2 |
5.5 |
0.1 |
3.5 |
87.7 |
7.20 |
14.28 |
0.0778 |
0.0615 |
||
500 |
26.4 |
5.5 |
0.1 |
3.8 |
96.0 |
9.15 |
17.80 |
0.0605 |
0.0487 |
10) 18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath |
Approx. Overall Dia. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
25 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
35 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
50 |
8.2 |
8.0 |
0.1 |
2.9 |
64.9 |
3.02 |
3.87 |
0.6410 |
0.4936 |
70 |
9.7 |
8.0 |
0.1 |
3.0 |
68.4 |
3.42 |
4.65 |
0.4430 |
0.3420 |
95 |
11.3 |
8.0 |
0.1 |
3.1 |
72.0 |
3.89 |
5.59 |
0.3200 |
0.2464 |
120 |
12.8 |
8.0 |
0.1 |
3.3 |
75.7 |
4.39 |
6.54 |
0.2530 |
0.1955 |
150 |
14.2 |
8.0 |
0.1 |
3.3 |
78.7 |
4.85 |
7.55 |
0.2060 |
0.1587 |
185 |
15.9 |
8.0 |
0.1 |
3.4 |
82.6 |
5.42 |
8.79 |
0.1640 |
0.1271 |
240 |
18.3 |
8.0 |
0.1 |
3.5 |
88.0 |
6.22 |
10.66 |
0.1250 |
0.0976 |
300 |
20.4 |
8.0 |
0.1 |
3.7 |
92.9 |
7.20 |
12.77 |
0.1000 |
0.0778 |
400 |
23.2 |
8.0 |
0.1 |
3.9 |
99.3 |
8.38 |
15.46 |
0.0778 |
0.0615 |
500 |
26.4 |
8.0 |
0.1 |
4.2 |
107.6 |
10.15 |
18.85 |
0.0605 |
0.0487 |
 High Performance Medium Voltage XLPE Insulated Unarmoured Power Cable
Application:
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.
Property:
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.
Specification:
Standard:
IEC60502,designing and manufacturing special power cable according to the other standards required by the customers.
1) 3.6/6(7.2)kV,3.6/6.6(7.2)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath |
Approx. Overall Dia. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
25 |
6.0 |
2.5 |
0.12 |
1.5 |
17.6 |
0.34 |
0.49 |
1.2000 |
0.7270 |
35 |
7.0 |
2.5 |
0.12 |
1.5 |
18.5 |
0.39 |
0.60 |
0.8680 |
0.5240 |
50 |
8.3 |
2.5 |
0.12 |
1.6 |
20.0 |
0.46 |
0.74 |
0.6410 |
0.3870 |
70 |
9.7 |
2.5 |
0.12 |
1.6 |
21.5 |
0.55 |
0.96 |
0.4430 |
0.2680 |
95 |
11.3 |
2.5 |
0.12 |
1.7 |
23.3 |
0.66 |
1.23 |
0.3200 |
0.1930 |
120 |
13 |
2.5 |
0.12 |
1.7 |
24.8 |
0.77 |
1.48 |
0.2530 |
0.1530 |
150 |
14.6 |
2.5 |
0.12 |
1.8 |
26.4 |
0.87 |
1.77 |
0.2060 |
0.1240 |
185 |
15.9 |
2.5 |
0.12 |
1.8 |
28.1 |
1.01 |
2.13 |
0.1640 |
0.0991 |
240 |
18.3 |
2.6 |
0.12 |
1.9 |
30.9 |
1.23 |
2.71 |
0.1250 |
0.0754 |
300 |
20.4 |
2.8 |
0.12 |
2.0 |
33.6 |
1.48 |
3.32 |
0.1000 |
0.0601 |
400 |
23.2 |
3.0 |
0.12 |
2.1 |
37.0 |
1.81 |
4.16 |
0.0778 |
0.0470 |
500 |
26.4 |
3.2 |
0.12 |
2.2 |
41.1 |
2.24 |
5.27 |
0.0605 |
0.0366 |
630 |
30.1 |
3.2 |
0.12 |
2.3 |
45.0 |
2.73 |
6.62 |
0.0469 |
0.0283 |
2) 6/10(12)kV,6.35/11(12)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath |
Approx. Overall Dia. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
|||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
|||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
|
25 |
6.0 |
3.4 |
0.12 |
1.5 |
19.4 |
0.40 |
0.55 |
1.2000 |
0.7270 |
|
35 |
6.9 |
3.4 |
0.12 |
1.6 |
20.5 |
0.45 |
0.66 |
0.8680 |
0.5240 |
|
50 |
8.2 |
3.4 |
0.12 |
1.6 |
21.8 |
0.52 |
0.80 |
0.6410 |
0.3870 |
|
70 |
9.7 |
3.4 |
0.12 |
1.7 |
23.5 |
0.62 |
1.03 |
0.4430 |
0.2680 |
|
95 |
11.3 |
3.4 |
0.12 |
1.7 |
25.1 |
0.73 |
1.30 |
0.3200 |
0.1930 |
|
120 |
12.8 |
3.4 |
0.12 |
1.8 |
26.8 |
0.85 |
1.56 |
0.2530 |
0.1530 |
|
150 |
14.2 |
3.4 |
0.12 |
1.8 |
28.2 |
0.95 |
1.85 |
0.2060 |
0.1240 |
|
185 |
15.9 |
3.4 |
0.12 |
1.9 |
30.1 |
1.10 |
2.22 |
0.1640 |
0.0991 |
|
240 |
18.3 |
3.4 |
0.12 |
2.0 |
32.7 |
1.33 |
2.80 |
0.1250 |
0.0754 |
|
300 |
20.4 |
3.4 |
0.12 |
2.0 |
34.8 |
1.54 |
3.39 |
0.1000 |
0.0601 |
|
400 |
23.2 |
3.4 |
0.12 |
2.2 |
38.0 |
1.87 |
4.22 |
0.0778 |
0.0470 |
|
500 |
26.4 |
3.4 |
0.12 |
2.2 |
41.5 |
2.26 |
5.29 |
0.0605 |
0.0366 |
|
630 |
30.1 |
3.4 |
0.12 |
2.4 |
45.6 |
2.78 |
6.67 |
0.0469 |
0.0283 |
3) 8.7/10(15)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath |
Approx. Overall Dia. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
|||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
|||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
|
25 |
6.0 |
4.5 |
0.12 |
1.6 |
21.8 |
0.48 |
0.63 |
1.2000 |
0.7270 |
|
35 |
6.9 |
4.5 |
0.12 |
1.7 |
22.9 |
0.54 |
0.75 |
0.8680 |
0.5240 |
|
50 |
8.2 |
4.5 |
0.12 |
1.7 |
24.2 |
0.61 |
0.89 |
0.6410 |
0.3870 |
|
70 |
9.7 |
4.5 |
0.12 |
1.8 |
25.9 |
0.72 |
1.13 |
0.4430 |
0.2680 |
|
95 |
11.3 |
4.5 |
0.12 |
1.8 |
27.5 |
0.84 |
1.40 |
0.3200 |
0.1930 |
|
120 |
12.8 |
4.5 |
0.12 |
1.9 |
29.2 |
0.96 |
1.67 |
0.2530 |
0.1530 |
|
150 |
14.2 |
4.5 |
0.12 |
1.9 |
30.6 |
1.06 |
1.96 |
0.2060 |
0.1240 |
|
185 |
15.9 |
4.5 |
0.12 |
2.0 |
32.5 |
1.22 |
2.34 |
0.1640 |
0.0991 |
|
240 |
18.3 |
4.5 |
0.12 |
2.1 |
35.1 |
1.46 |
2.93 |
0.1250 |
0.0754 |
|
300 |
20.4 |
4.5 |
0.12 |
2.1 |
37.2 |
1.68 |
3.52 |
0.1000 |
0.0601 |
|
400 |
23.2 |
4.5 |
0.12 |
2.2 |
40.2 |
2.00 |
4.35 |
0.0778 |
0.0470 |
|
500 |
26.4 |
4.5 |
0.12 |
2.3 |
43.9 |
2.43 |
5.45 |
0.0605 |
0.0366 |
|
630 |
30.1 |
4.5 |
0.12 |
2.4 |
47.8 |
2.93 |
6.83 |
0.0469 |
0.0283 |
4) 12/20(24)kV, 12.7/22(24)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath |
Approx. Overall Dia. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
25 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
35 |
6.9 |
5.5 |
0.12 |
1.7 |
24.9 |
0.62 |
0.83 |
0.8680 |
0.5240 |
50 |
8.2 |
5.5 |
0.12 |
1.8 |
26.4 |
0.70 |
0.98 |
0.6410 |
0.3870 |
70 |
9.7 |
5.5 |
0.12 |
1.8 |
27.9 |
0.80 |
1.21 |
0.4430 |
0.2680 |
95 |
11.3 |
5.5 |
0.12 |
1.9 |
29.7 |
0.94 |
1.50 |
0.3200 |
0.1930 |
120 |
12.8 |
5.5 |
0.12 |
1.9 |
31.2 |
1.05 |
1.77 |
0.2530 |
0.1530 |
150 |
14.2 |
5.5 |
0.12 |
2.0 |
32.8 |
1.17 |
2.07 |
0.2060 |
0.1240 |
185 |
15.9 |
5.5 |
0.12 |
2.0 |
34.5 |
1.33 |
2.45 |
0.1640 |
0.0991 |
240 |
18.3 |
5.5 |
0.12 |
2.1 |
37.1 |
1.57 |
3.04 |
0.1250 |
0.0754 |
300 |
20.4 |
5.5 |
0.12 |
2.2 |
39.4 |
1.81 |
3.66 |
0.1000 |
0.0601 |
400 |
23.2 |
5.5 |
0.12 |
2.3 |
42.4 |
2.14 |
4.49 |
0.0778 |
0.0470 |
500 |
26.4 |
5.5 |
0.12 |
2.4 |
46.1 |
2.58 |
5.61 |
0.0605 |
0.0366 |
630 |
30.1 |
5.5 |
0.12 |
2.4 |
49.8 |
3.10 |
6.99 |
0.0469 |
0.0283 |
5) 18/30(36)kV,19/33(36)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath |
Approx. Overall Dia. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
|||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
|||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
|
25 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
|
35 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
|
50 |
8.2 |
8.0 |
0.12 |
2.0 |
31.8 |
0.95 |
1.23 |
0.6410 |
0.3870 |
|
70 |
9.7 |
8.0 |
0.12 |
2.0 |
33.3 |
1.07 |
1.47 |
0.4430 |
0.2680 |
|
95 |
11.3 |
8.0 |
0.12 |
2.1 |
35.1 |
1.21 |
1.78 |
0.3200 |
0.1930 |
|
120 |
12.8 |
8.0 |
0.12 |
2.1 |
36.6 |
1.34 |
2.05 |
0.2530 |
0.1530 |
|
150 |
14.2 |
8.0 |
0.12 |
2.2 |
38.2 |
1.47 |
2.37 |
0.2060 |
0.1240 |
|
185 |
15.9 |
8.0 |
0.12 |
2.2 |
39.9 |
1.64 |
2.76 |
0.1640 |
0.0991 |
|
240 |
18.3 |
8.0 |
0.12 |
2.3 |
42.5 |
1.90 |
3.37 |
0.1250 |
0.0754 |
|
300 |
20.4 |
8.0 |
0.12 |
2.4 |
44.8 |
2.16 |
4.01 |
0.1000 |
0.0601 |
|
400 |
23.2 |
8.0 |
0.12 |
2.4 |
47.6 |
2.52 |
4.87 |
0.0778 |
0.0470 |
|
500 |
26.4 |
8.0 |
0.12 |
2.5 |
51.3 |
2.98 |
6.01 |
0.0605 |
0.0366 |
|
630 |
30.1 |
8.0 |
0.12 |
2.6 |
55.2 |
3.54 |
7.43 |
0.0469 |
0.0283 |
6) 3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath |
Approx. Overall Dia. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
||||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
||||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
||
25 |
6.0 |
2.5 |
0.1 |
2.0 |
34.6 |
1.13 |
1.58 |
1.2000 |
0.7270 |
||
35 |
6.9 |
2.5 |
0.1 |
2.1 |
36.8 |
1.29 |
1.92 |
0.8680 |
0.5240 |
||
50 |
8.2 |
2.5 |
0.1 |
2.2 |
39.8 |
1.51 |
2.36 |
0.6410 |
0.3870 |
||
70 |
9.7 |
2.5 |
0.1 |
2.3 |
43.2 |
1.81 |
3.04 |
0.4430 |
0.2680 |
||
95 |
11.3 |
2.5 |
0.1 |
2.4 |
46.9 |
2.17 |
FUNCTION DESCRIPTION
Countdown socket has an AC outlet, the maximum can output 230 V16A of power, there are two control modes, that is, countdown off and countdown on. It is convenient to control the equipment which needs to switch off or turn on AC. improve the safety of the use of some equipment and save more energy.
SET Timer
1,Countdown plug in the socket, all indicator lights red flash three times, at this time the socket has no output, for the normal state, into the countdown state. Click the button, the first red light up, the socket output after an hour off, and then short press the button can set the socket timing of 2 H.4H.6H.8H.10H.OFF.
2,Long press button 3s, all indicator lights green flash three times, at this time the socket has output, for the regular open state, into the countdown on state. Click on the button, the first green light on, the socket is closed an hour later, and then press the button to set the socket countdown 2 H.4H.6H.8H.10H.OFF.
3,Press button 3 longer S, all indicator lights red light flash 3 times again into countdown mode.
4,Select the required countdown time mode, the corresponding mode countdown lights up, start countdown until the end of the countdown time. The outlet that controls the output will start or stop the output.
5,After the countdown starts, the time indicator will change automatically from high to low until the countdown is over.
NOTE:
1,Check that the power connection is good.
2,Use only indoors and in dry places.
3,This product does not convert AC voltage.
4,Maximum load not exceeding 16A 3680W.
5,Grounding is required for safety. 6,Any questions, please contact the electrician. countdown timer socket, countdown timer plug, Countdown digital timer, Countdown socket, countdown switch socket NINGBO COWELL ELECTRONICS & TECHNOLOGY CO., LTD , https://www.cowellsocket.com |