Type MP-Gc, Mining Cable, Cu/Epr/CPE, 3/C, 25kv (ICEA S-75-381/NEMA WC-58)

Model NO.: Type MP-GC
Material Shape: Round Wire
Range of Application: Mine
Certification: ISO9001, CCC
Brand: Boan
Rated Voltage: 25 Kv
Size: 1-500 AWG or Mcm
Number of Cores: 3
Trademark: DingAn or OEM
Specification: SGS
Origin: Jiangsu Yixing, China
HS Code: 8544492100
Model NO.: Type MP-GC
Material Shape: Round Wire
Range of Application: Mine
Certification: ISO9001, CCC
Brand: Boan
Rated Voltage: 25 Kv
Size: 1-500 AWG or Mcm
Number of Cores: 3
Trademark: DingAn or OEM
Specification: SGS
Origin: Jiangsu Yixing, China
HS Code: 8544492100
Type MP-GC, Mining Cable, Cu/EPR/CPE, 3/C, 25KV (ICEA S-75-381/NEMA WC-58)

Features
True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.


Application
High voltage distribution intended for permanent installations. Suitable for underground mining and boreholes. Can be used in aerial nstallations, ducts or direct burial.

Standards
ICEA S-75-381/NEMA WC-58 Portable and Power Feeder Cables for Use in Mines and Similar Applications.

Specifications
Maximum operating voltage: 5 kV to 35 kV 100% and 133% IL
Maximum conductor operation temperatures: Wet and dry locations
Normal: 90 °C
Emergency: 130 °C
Short Circuit: 250 °C


Engineering Information
1. Phase, Grounding and Ground Check Conductors: Soft or annealed uncoated copper compressed Class B stranding, or unilay-compressed per ASTM B8. On request, compacted strand. Sizes: 6 AWG up to 500 kcmil.
2. Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
3. Insulation: Thermoset ethylene propylene rubber (EPR).
4. Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
5. Metallic Shield: Soft annealed copper tape, 2.5 mil minimum thickness, 10% minimum overlap. Phase ID: Color printed on the extruded conducting layer, BL, WH, RE.
6. Ground Check: Thermosetting insulation yellow colored for identification.
7. Assembly: Phase conductors cabled with the ground check between the BL and WH phase conductors, two grounding conductors in inmate contact with the shields, placed on the remaining interstices, suitable fillers, as required and binder tape.
8. Jacket: Black sunlight resistance and flame retardant chlorinated polyethylene (CPE) compound. On request, PVC jacket.

Constructon No. of Strands Grounding Conductor Size Control Conductor Size Nominal Insulaton Thickness Nominal Jacket Thickness Nominal Overall Diameter Nominal Weight Ampacity
No. of cores×AWG/kcmil
AWG/kcmil AWG/kcmil inch inch inch lbs/kf A
3×1 19 5 8 0.26 0.14 2.37 3435 187
3×1/0 19 4 8 0.26 0.140 2.45 3815 218
3×2/0 19 3 8 0.26 0.140 2.54 4290 249
3×3/0 19 2 8 0.26 0.140 2.65 4875 286
3×4/0 19 1 8 0.26 0.140 2.81 5665 327
3×250 37 1/0 8 0.26 0.170 2.97 6495 360
3×350 37 2/0 8 0.26 0.170 3.18 7970 438
3×500 37 4/0 8 0.26 0.170 3.45 10300 536
  Type MP-GC, Mining Cable, Cu/EPR/CPE, 3/C, 25KV (ICEA S-75-381/NEMA WC-58)

Features
True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.


Application
High voltage distribution intended for permanent installations. Suitable for underground mining and boreholes. Can be used in aerial nstallations, ducts or direct burial.

Standards
ICEA S-75-381/NEMA WC-58 Portable and Power Feeder Cables for Use in Mines and Similar Applications.

Specifications
Maximum operating voltage: 5 kV to 35 kV 100% and 133% IL
Maximum conductor operation temperatures: Wet and dry locations
Normal: 90 °C
Emergency: 130 °C
Short Circuit: 250 °C


Engineering Information
1. Phase, Grounding and Ground Check Conductors: Soft or annealed uncoated copper compressed Class B stranding, or unilay-compressed per ASTM B8. On request, compacted strand. Sizes: 6 AWG up to 500 kcmil.
2. Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
3. Insulation: Thermoset ethylene propylene rubber (EPR).
4. Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
5. Metallic Shield: Soft annealed copper tape, 2.5 mil minimum thickness, 10% minimum overlap. Phase ID: Color printed on the extruded conducting layer, BL, WH, RE.
6. Ground Check: Thermosetting insulation yellow colored for identification.
7. Assembly: Phase conductors cabled with the ground check between the BL and WH phase conductors, two grounding conductors in inmate contact with the shields, placed on the remaining interstices, suitable fillers, as required and binder tape.
8. Jacket: Black sunlight resistance and flame retardant chlorinated polyethylene (CPE) compound. On request, PVC jacket.

Constructon No. of Strands Grounding Conductor Size Control Conductor Size Nominal Insulaton Thickness Nominal Jacket Thickness Nominal Overall Diameter Nominal Weight Ampacity
No. of cores×AWG/kcmil
AWG/kcmil AWG/kcmil inch inch inch lbs/kf A
3×1 19 5 8 0.26 0.14 2.37 3435 187
3×1/0 19 4 8 0.26 0.140 2.45 3815 218
3×2/0 19 3 8 0.26 0.140 2.54 4290 249
3×3/0 19 2 8 0.26 0.140 2.65 4875 286
3×4/0 19 1 8 0.26 0.140 2.81 5665 327
3×250 37 1/0 8 0.26 0.170 2.97 6495 360
3×350 37 2/0 8 0.26 0.170 3.18 7970 438
3×500 37 4/0 8 0.26 0.170 3.45 10300 536
 

Pearl Cotton Bag Cutting Machine

Pearl Cotton Bag Cutting Machine,Front Sealing Bag Cutting Machine,High-Speed Bag Cutting Machine,Square Bottom Bag Cutting Machine

Dongguan Yuantong Technology Co., Ltd. , https://www.ytbagmachine.com