Model NO.: APDM160 APDM630 DHN HR17
Standard: GB13539\IEC60269 and BS88
Rated Curerent: 200A,400A,630A
Rated Voltage: AC 400V/500V/690V
Trademark: HENUO
Transport Package: International Standard Export Carton
Specification: ce
Origin: Zhejiang China
HS Code: 853610000
APDM 160-Single Phase switch for NH type fuses up to 160AGeneral Description
The APDMl60 fuse switch it is used either as an operation or protection device for LV lines .It is designed to be used with NH 00 size fuses offering a maximum of 160 Amps of line protection without blades .
In case blades are used ,the maximum switching load would be 250A .It is manufactured in reinfored fiberglass polyamide and fulfills all the necessary requirements for outdoor installation and operation .
In the APDM 160C model the connection is made with connectors suitable for aluminum and copper conductors with a section range between 16 and 95 mm2 (5-4/0 AWG) .
The APDMl60 model can also be connected with terminals lugs and both models can be installed with single phase or three phase opening .
They have special sockets to obtain a compact set .
The switch is operated from the ground with an operating rod and also has an indicator to show if the fuse is placed .It can be sealed with security ties . It also has a led to show the fusion of the fuse .
Technical Characteristics
Voltage | 500V |
Insulation level | 1000V |
Frequency | 50/60Hz |
Operational current with fuse | 160A |
Operational current with blades | 250A |
Installation category | AC22 |
Short lasting current (1s) | 3,2kA |
Dynamic current (crest ) | 25KA |
Interruption capacity | 100KA |
Minimum mechanical life (operation ) | 1000 |
Weight | 600G |
Protection range | IP23 |
APDM 630-Single Phase switch for NH type fuses up to 630A
General Description
The APDM630 fuse switch it is used either as an operation or protection device for LV lines .It is designed to be used with NH 1-2or 3 size fuses offering a maximum of 630 Amps of line protection without blades .
In case blades are used ,the maximum switching load would be 800 Amps .
It is manufactured in reinforced fiberglass polyamide and fulfills all the necessary requirements for outdoor installation and operation .
In the APDM 160C model the connection is made with connectors suitable for aluminum and copper conductors with a section range between 16 and 95 mm2 (5-4/0 AWG) .
The closure of the cap allows the switch to be closed with or without a fuse ,preventing the risk of leaving tension parts exposed .It may also be provided with a light emission diode(LED) .
Technical Characteristics
Voltage | 500V |
Insulation level | 1000V |
Frequency | 50/60Hz |
Operational current with fuse | 630A |
Operational current with blades | 800A |
Installation category | AC22 |
Short lasting current (1s) | 12kA |
Dynamic current (crest ) | 50KA |
Interruption capacity | 100KA |
Minimum mechanical life (operation ) | 1000 |
Weight | 1.8kg |
Protection range | IP23 |
APDM 630-3 Four phase switch for NH type fuses up to 630A ,with three phase operation
General Description
This model is suitable for switching and protecting LV overhead lines ,and/or to include a protection when doing a connection to low voltage underground systems . The design of this equipment allows the opening and closing of the three phases simultaneously and independently from the neutral,which is clearly identified to prevent its disconnection in rigidly limited systems .If required ,it can be easily transformed in a single phase operation switch as the standard model APDM 630 It can be connected with terminals lugs(APDM 630-3)or directly with its connectors (APDM 630-3C) .
Each phase and the neutral have an indicator which show if the fuse or the blade are installed .The closure of the cap allows the switch to be closed with or without the fuse preventing the risk of leaving live parts exposed It can also be provided with a led to show the fusion of the fuses .
Technical Characteristics
Voltage | 500V |
Insulation level | 1000V |
Frequency | 50/60Hz |
Operational current with fuse | 630A |
Operational current with blades | 800A |
Installation category | AC22 |
Short lasting current (1s) | 12kA |
Dynamic current (crest ) | 50KA |
Interruption capacity | 100KA |
Operations behavior without load (open) | 800 |
Operations behavior without load (operation ) (400 A Cos fi 0,65) |
200 |
Weight | 1.8kg |
Protection range | IP23 |