- Model NO.: CLG-100
- Output Type: DC
- Color: White
- Internal Structure: On-Off Type
- Connection: Screw
- Brand: Meanwell
- Trademark: Meanwell
- Specification: Universal
- HS Code: 8504401400
- Usage: Laptop, Switching, Mobile Phone, Game Player, Digital Camera, Phone, Display, LED Strip
- Certification: TUV, RoHS, UL, ISO9001, CCC
- Type: OEM
- Power Source: Full-Bridge Type
- Bluetooth Standard: 1.1
- Size: 222.2*68*38.8mm
- Transport Package: Paper Carton
- Origin: Guangdong China (Mainland)
Original Meanwell CLG-100 Series Single Output Waterproof IP67 LED Driver Features:
1. Universal AC input / Full range (up to 295VAC)
2. Built-in active PFC function
3. High efficiency up to 89%
4. Protections: Short circuit / Over current / Over voltage / Over temperature
5. Cooling by free air convection
6. IP67 design for indoor or outdoor installations
7. Class 2 power unit
8. Pass LPS
9. 100% full load burn-in test
10. High reliability
11. Suitable for LED lighting and moving sign applications (Note.2)
12. Compliance to worldwide safety regulations for lighting
13. Suitable for dry / damp / wet locations
14. 3 years warranty
Original Meanwell CLG-100 Series Single Output Waterproof IP67 LED Driver Specifications:
Â
MODEL | CLG-100-12 | CLG-100-15 | CLG-100-20 | CLG-100-24 | CLG-100-27 | CLG-100-36 | CLG-100-48 | |
OUTPUT | DC VOLTAGE | 12V | 15V | 20V | 24V | 27V | 36V | 48V |
CONSTANT CURRENT REGION Note.7 | 9 ~ 12V | 11.25 ~ 15V | 15 ~ 20V | 18 ~ 24V | 20.25 ~ 27V | 27 ~ 36V | 36 ~ 48V | |
RATED CURRENTÂ Â Â Â Â Â Â Note.5 | 5A | 5A | 4.8A | 4A | 3.55A | 2.65A | 2A | |
RATED POWERÂ Â Â Â Â Â Â Â Â Â Â Note.5 | 60W | 75W | 96W | 96W | 95.85W | 95.4W | 96W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | Fixed. Can be modified between 0% ~ -15% rated output voltage | |||||||
CURRENT ADJ. RANGE | Fixed. Can be modified between 3% ~ -25% rated output current | |||||||
VOLTAGE TOLERANCE Note.3 | ±3.0% | ±3.0% | ±3.0% | ±3.0% | ±3.0% | ±2.0% | ±2.0% | |
LINE REGULATION | ±1.0% | |||||||
LOAD REGULATION | ±2.0% | |||||||
SETUP, RISE TIME | 500ms, 80ms / 230VACÂ Â Â 1200ms, 80ms / 115VAC at full load | |||||||
HOLD UP TIME (Typ.) | 60ms / 230VACÂ Â Â 30ms / 115VAC at full load | |||||||
INPUT | VOLTAGE RANGEÂ Â Â Â Â Â Â Note.4 | 90 ~ 295VACÂ Â Â 127 ~ 417VDC | ||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||
POWER FACTOR (Typ.) | PF>0.95/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve) | |||||||
TOTAL HARMONIC DISTORTION | THD< 20% when output loading>=75% at 115VAC/230VAC input and output loading>=75% at 277VAC input | |||||||
EFFICIENCY (Typ.) | 83% | 85% | 88.5% | 88.5% | 88% | 88% | 88.5% | |
AC CURRENT (Typ.) | 12V:0.8A/115VAC 0.4A/230VAC 0.3A/277VACÂ Â Â 15V:0.9A/115VAC 0.45A/230VAC 0.35A/277VAC 20V ~ 48V:1.1A/115VAC 0.55A/230VAC 0.45A/277VAC |
|||||||
INRUSH CURRENT(Typ.) | COLD START 40A(twidth=1030μs measured at 50% Ipeak) at 230VAC | |||||||
MAX. No. of PSUs on 16A | 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC | |||||||
LEAKAGE CURRENT | <0.75mA / 240VAC | |||||||
PROTECTION | OVER CURRENT (Typ.) | 95 ~ 102% | ||||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | ||||||||
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed | |||||||
OVER VOLTAGE | 13 ~ 16V | 16.5 ~ 20V | 22 ~ 27V | 27 ~ 34V | 30 ~ 36V | 39 ~ 48V | 52 ~ 64V | |
Protection type : Shut down and latch off o/p voltage, re-power on to recover | ||||||||
OVER TEMPERATURE | Shut down o/p voltage, re-power on to recover | |||||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70ºC (Refer to "Derating Curve") | ||||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |||||||
STORAGE TEMP., HUMIDITY | -40 ~ +80ºC, 10 ~ 95% RH | |||||||
TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 50ºC) | |||||||
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | |||||||
SAFETY & EMC |
SAFETY STANDARDSÂ Â Note.8 | UL879, UL8750, UL1310, TUV EN61347-1, EN61347-2-13 independent, CAN/CSA C22.2 No. 223-M91(except for 48V), CSA C22.2 No. 250.0-08(except for 48V), CSA C22.2 No. 207-M89(except for 48V), TUV EN60950-1, IP67, J61347-1, J61347-2-13 approved |
||||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||||||
ISOLATION RESISTANCE | I/P-O/P:100M Ohms / 500VDC / 25ºC/ 70% RH | |||||||
EMC EMISSION | Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (>=75% load) ; EN61000-3-3 | |||||||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A | |||||||
OTHERS | MTBF | 301Khrs min. MIL-HDBK-217F (25ºC) | ||||||
DIMENSION | 222.2*68*38.8mm (L*W*H) | |||||||
PACKING | 1.0Kg; 12pcs/13Kg/0.58CUFT | |||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltages. Please check the static characteristics for more details. 5. This is the maximum possible output current and power, over load protection may be activated slightly below this level to comply with the requirement of UL1310 class 2. 6. 3 years warranty is guaranteed for operating ambient temperature no higher than 68ºC. 7. Please refer to "DRIVING METHODS OF LED MODULE". 8. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18. 9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 10. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains. |
Â
Â
Provide you with the supply of pulse oximeter finger. to help you safely get back to your daily routine.
With more than 15+ yrs rich MFG experience, you can definitely trust in and cooperate with.
Our strict quality control protocol thoroughly vets every aspect of production, storage, and shipments all the way way to our end customers.
Our products include pulse Oximeter Finger, Forehead Thermometer, Automatic foam soap dispenser, etc.
Pulse Oximeter Manufacturers, oxygen saturation, oximetry
TOPNOTCH INTERNATIONAL GROUP LIMITED , https://www.itopnoobluetoothes.com